Description

This testcases creates monitored items with a queue size of 2 and provokes queue overflows. However the script does not check the revised queue size but assumes it is always the requested size, which may not be the case as e.g. micro embedded servers may limit the maximum queue size to 1. The scripts proceeds and then reports a too high overflow count as error.

Steps To Reproduce

Run this testcase with a server with maximum queue size of 1, e.g. HP SDK Demoserver with max_monitoreditem_queue_size set to 1.

TagsNo tags attached.
Files Affected

Activities

Sebastian Allmendinger

2020-11-27 16:43

developer   ~0013312

The revised QueueSize is now taken into account when calculating the value of MonitorQueueOverflowCount.

Paul Hunkar

2020-12-03 17:30

administrator   ~0013368

reviewed in cmp meeting

Issue History

Date Modified Username Field Change
2020-11-10 15:03 fishfrak New Issue
2020-11-23 14:50 Paul Hunkar Assigned To => AlexanderAllmendinger
2020-11-23 14:50 Paul Hunkar Status new => assigned
2020-11-27 16:43 Sebastian Allmendinger Assigned To AlexanderAllmendinger => Sebastian Allmendinger
2020-11-27 16:43 Sebastian Allmendinger Status assigned => resolved
2020-11-27 16:43 Sebastian Allmendinger Resolution open => fixed
2020-11-27 16:43 Sebastian Allmendinger Fixed in Version => 1.03.341.397
2020-11-27 16:43 Sebastian Allmendinger Note Added: 0013312
2020-12-03 17:30 Paul Hunkar Status resolved => closed